Ventricular septal defect following mitral valve replacement

Jose Arriola-Montenegro,Rishabh Tandon,Andrew Shaffer,Prabhjot S Nijjar
DOI: https://doi.org/10.1093/ejcts/ezae029
IF: 4.534
2024-01-30
European Journal of Cardio-Thoracic Surgery
Abstract:Abstract Mitral valve surgery (MVS), with repair preferred to replacement, is a common procedure for the treatment of severe primary mitral regurgitation related to leaflet prolapse. Structural complications after MVS include left ventricular outflow obstruction, paravalvular leak and atrial septal defect. Intraoperative transoesophageal echocardiography and predischarge transthoracic echocardiography (TTE) specifically screen for these complications. Ventricular septal defect (VSD), a known complication after aortic valve surgery, is rarely reported after MVS. Recently, unsuccessful valvuloplasty prior to replacement was suggested as a risk factor. We present such a case and explore mechanisms with advanced cardiac imaging. In this case, the patient was found to have an elongated membranous septum that likely predisposed her to septal injury. Finally, we provide guidance on specific transoesophageal/transthoracic echocardiography views to avoid a missed diagnosis.
surgery,cardiac & cardiovascular systems,respiratory system
What problem does this paper attempt to address?