Trigger-free LIBS using kHz and a few mJ Laser in combination with random forest regression for quantitative analysis of steel elements

Sunita Ahlawat,Amarjeet Singh,Satish Sahu,Pranab K Mukhopadhyay,Rajesh Arya,S. K. Dixit
DOI: https://doi.org/10.1039/d4ja00060a
2024-05-25
Journal of Analytical Atomic Spectrometry
Abstract:In this work, use of a low pulse energy and high repetition rate diode pumped solid state laser has been investigated for trigger-free laser induced breakdown spectroscopy (LIBS) based quantitative analysis of commonly used steel grades. Due to the low pulse energy of 2 mJ, signal was accumulated over large number of pulses to have good signal quality and was acquired in a free-running mode i.e. without any triggering. Thuough, the trigger-free signal acquisition lacked continuum suppression capability, weak plasma events caused by the low pulse energy did not produce significant continuum and hence continuum suppression was not an issue. Further, the 2 kHz repetition rate of laser required that the sample be continuously scanned to avoid signal decay as a result of formation of excessively deep craters. As scanning could introduce additional signal fluctuations therefore, a combination of sample scanning velocity and pulse energy which led to least signal fluctuations, was used to acquire LIBS spectra from steel samples. Of the total 19 samples, 15 steel samples were used to train random forest regression models for quantitative analysis of various elements including C, Si, Mn, Cr, Ni, Mo, Cu and Co. Remaining 4 samples were used for testing/validating the models. It was observed that as compared to the full spectral range of ~ 185 nm - 545 nm, a smaller and information rich spectral range of ~185 nm - 310 nm produced better results. With the selected spectral range, the relative mean error (RME) ranged from 1.4% to 15.77 %, with lower values belonging to major elements and higher values to minor elements. The root mean square error (RMSE) values were found to range from 0.014 wt.% for C to 0.26 wt.% for Ni. The R2 values, which indicated correlation between predicted and reference concentrations, were found to be > 96% for all the elements except Si and Cu. These results suggested that a trigger-free LIBS based on a low pulse energy, high repetition rate laser and a single channel spectrometer covering a narrow spectral range, in combination with machine learning techniques is suitable for quantitative analysis of steel elements.
spectroscopy,chemistry, analytical
What problem does this paper attempt to address?