Performance of a cryogenic system prototype for the XENON1T detector

E Aprile,R Budnik,B Choi,H A Contreras,K L Giboni,L W Goetzke,R F Lang,K E Lim,A J Melgarejo,G Plante,A Rizzo,P Shagin
DOI: https://doi.org/10.1088/1748-0221/7/10/p10001
2012-10-01
Journal of Instrumentation
Abstract:We have developed an efficient cryogenic system with heat exchange and associated gas purification system as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 tons of liquid xenon (LXe) at a temperature of 175K as target and detection medium for a dark matter search. In this paper we report results on the cryogenic system performance focusing on the dynamics of the gas circulation-purification through a heated getter, at flow rates above 50 Standard Liter per Minute (SLPM). A maximum flow of 114 SLPM has been achieved, and using two heat exchangers in series, a heat exchange efficiency better than 96% has been measured.
instruments & instrumentation
What problem does this paper attempt to address?