Validation of pathogen reduced plasmas from maxi‐pools combined with fast thawing

Marja‐Kaisa Auvinen,Folke Knutson,Helena Löf
DOI: https://doi.org/10.1111/tme.13106
2024-11-07
Transfusion Medicine
Abstract:Objectives Fast thawing for emergency situations and reduction of plasma wastage. Background Evaluation of plasma units, pooled and pathogen reduced (PR) in "maxi‐pools" with amotosalen and UVA light, and fast thawing. Methods/Materials Per replicate, 10 WB‐derived leukocyte depleted plasma units were frozen within 24 h at ≤ −25°C and stored for 7 days. After thawing, a maxi‐pool was constituted from the 10 units. After splitting into 4 sub‐pools of 650 mL, the sub‐pools were PR treated then split into 3 units resulting in 12 PR plasma units at 200 mL. Hundred and twenty PR plasma units were produced in total. The units were frozen at ≤ −25°C for 1 week, then thawed either in a fast plasma thawer for 5 min or in other control devices (17 to 23 min). FVIII:C, Fibrinogen, albumin, IgG, protein S and VWF were measured in plasma units, maxi‐pools and plasmas after PR treatment and thawing. Results There was a statistically significant (p
hematology
What problem does this paper attempt to address?