Causes and analysis of failure of bearing cage at non-driven end of wind turbine generator

Linfei Xiao,Zhunbei Zheng,Yongsheng Tan,Zhanjun Yang,Jianwei Zhang,Ning Zhou,Jingming Yan,Junjie Li,Jing Chen,Yuxing Wu,Hua He,Yongzhi Zhang
DOI: https://doi.org/10.1016/j.engfailanal.2024.108991
IF: 4
2024-10-27
Engineering Failure Analysis
Abstract:The non-driving end bearing cage of a wind turbine generator experienced a fracture and subsequent failure. In order to understand the reasons behind this failure, various analyses were conducted including examination of the metallographic structure, mechanical properties, fracture surface morphology, bearing vibration, and operating temperature of the cage. Through this analysis, the fracture process of the cage was deduced. The findings indicate that the fracture of the bearing cage was directly caused by the abnormal installation of the spacer. The eccentricity of the axial component resulted in ductile fracture, while the eccentricity of the radial component led to brittle fractures.
engineering, mechanical,materials science, characterization & testing
What problem does this paper attempt to address?