0993 A Senseless Sensing Lead: A Case Of Failed Sensing Lead In Hypoglossal Nerve Stimulator

Andrea Fekete,Aarti Grover,Wei He,Joel Oster,Peter Ostrow,Greg Schumaker,Richard Wein,Rajesh Zacharias
DOI: https://doi.org/10.1093/sleep/zsad077.0993
IF: 6.313
2023-05-01
SLEEP
Abstract:Abstract Introduction The hypoglossal nerve stimulator (HGNS) is an implanted device used to treat moderate to severe obstructive sleep apnea (OSA), offering an alternative form of therapy to continuous positive airway pressure. Currently, the Inspire® Upper Airway Stimulation (UAS) system is the only such device approved by the U.S. Food and Drug Administration (FDA). Report of case(s) We present a case of sensory lead malfunction in a 54-year-old man with moderate OSA who underwent HGNS implant in 2018 with the three-incision method and the sensory lead positioned in the 6th intercostal space. December 2022, the patient presented with right sided chest pain and subjective fever at outside hospital. A CT chest performed was significant for trace right sided pleural effusion and concern for pleural penetration of the sensory lead. Device interrogation in our office showed increased impedances and abnormal waveforms prompting discontinuation of therapy and scheduling a surgical revision. He denied any trauma, injury to the area and had been doing well overall but did feel as if the device wasn’t syncing appropriately with his breathing. In addition, his most recent sleep study on fairly high amplitude of 3.6V had persistent severe supine disease. During the surgery, the sensory lead was noted to be in its original placement site with intact anchors and sutures holding it in place. After the lead was removed there was noted to be a discoloration deep to the protective covering suggesting potential lead failure related to compromise of device. Conclusion Since its FDA approval in 2014, over 20,000 HGNS devices have been implanted in the USA and long-term data collection of efficacy and safety is ongoing. The Manufacturer and User Facility Device Experience (MAUDE) is a publicly available database of device-related adverse events reported to the FDA. At the time of this abstract, there are 714 reports related to HGNS of which 147 involve the respiratory sensory lead and 95 of these relate to pain and/or malfunction most commonly due to sensor tip separation and migration from lead body. This case illustrated a presentation of sensory lead malfunction due to presumed electrical leakage from insulation breach. Support (if any)
neurosciences,clinical neurology
What problem does this paper attempt to address?