Usefulness of a new polyvinyl alcohol hydrogel (PVA-H)-based simulator for endoscopic submucosal dissection training: a pilot study

Dong Seok Lee,Gin Hyug Lee,Sang Gyun Kim,Kook Lae Lee,Ji Won Kim,Ji Bong Jeong,Yong Jin Jung,Hyoun Woo Kang
DOI: https://doi.org/10.5946/ce.2022.163
2023-05-18
Clinical Endoscopy
Abstract:Background/Aims We developed a new endoscopic submucosal dissection (ESD) simulator and evaluated its efficacy and realism for use training endoscopists. Methods An ESD simulator was constructed using polyvinyl alcohol hydrogel sheets and compared to a previous ESD simulator. Between March 1, 2020, and December 30, 2021, eight expert endoscopists from three different centers analyzed the procedure-related factors of the simulator. Five trainees performed gastric ESD exercises under the guidance of these experts. Results Although the two ESD simulators provided overall favorable outcomes in terms of ESD-related factors, the new simulator had several benefits, including better marking of the target lesion’s limits (p<0.001) and overall handling (p<0.001). Trainees tested the usefulness of the new ESD simulator. The complete resection rate improved after 3 ESD training sessions (9 procedures), and the perforation rate decreased after 4 sessions (12 procedures). Conclusions We have developed a new ESD simulator that can help beginners achieve a high level of technical experience before performing real-time ESD procedures in patients. Keywords: Endoscopic submucosal dissection; Endoscopy; Hydrogels; Polyvinyl alcohol; Simulation training
What problem does this paper attempt to address?