Behavior of foam concrete flat panel and applications of foam concrete in construction works

Haitham AL-Thairy,Seyed Alireza Zareei,Ali Kadhim Sallal,Dhoha Saad Hanoon
DOI: https://doi.org/10.1007/s41062-023-01148-z
2023-05-31
Innovative Infrastructure Solutions
Abstract:This research includes two parts: experimental study, which includes casting fifty-four specimens of dimensions 40 × 25 × 10 cm3documentclass[12pt]{minimal}usepackage{amsmath}usepackage{wasysym}usepackage{amsfonts}usepackage{amssymb}usepackage{amsbsy}usepackage{mathrsfs}usepackage{upgreek}setlength{oddsidemargin}{-69pt}egin{document}$${mathrm{cm}}^{3}$$end{document} and then tested after 7, 14, and 28 days and study the compressive strength, the tensile strength, the modulus of elasticity, water absorption, and modulus of rupture of all panels, the second part includes a study of the various applications of foam concrete used in various construction applications used in different countries around the world. From results, using sand in the concrete mix gives the best results in terms of increased the strength and also increased the density of foam concrete as compared with fly ash, which cause to increase the strength of foam concrete very slightly. The compressive strength of the specimens increases with increase in the amount of sand or carbon fiber content in it, compared to other specimens that contain less amount of sand or carbon fiber, also the average tensile strength of the specimens that cast from cement, sand, fly ash, and carbon fiber were the best as compared with specimens that cast from cement and fly ash or cast from cement and sand only. Specimens that contain fiber are considered stronger than specimens that do not contain fiber in terms of resisting the loads that applied on them during its testing; the specimen Z that cast from cement, sand, fly ash, and fiber is the best between all other specimens, while the specimen A that cast from cement and fly ash only is considered the weakest. Specimens that contains fly ash in its composition has a lower modulus of elasticity than specimens that contains sand in its composition, and the reason for this is due to the fact that sand contains a large percentage of fine aggregate, while fly ash does not contain fine aggregate, but contains entirely paste only. The absorption rate of specimens that contain sand and fly ash together in their composition is less than the specimens that contain sand only or specimens that contain fly ash only. Using carbon fibers in the concrete mix reduces the absorption rate twice, due to the closure of the pores in the foamed concrete.
What problem does this paper attempt to address?