High SNR ultrasonic imaging of crack defects in particles filled composite explosives
Hai-Ning Li,Li-Da Yu,Ren-Jie Gan,Wei-Bin Zhang,Zhan-Feng Yang,Li Hai-Ning,Yu Li-Da,Gan Ren-Jie,Zhang Wei-Bin,Yang Zhan-Feng,,,
DOI: https://doi.org/10.7498/aps.72.20230522
IF: 0.906
2023-01-01
Acta Physica Sinica
Abstract:Polymer Bonded Explosives (PBX) is a kind of composite materials with highly filled molding explosive particles (normally more than 95%) and a small amount of binders (less than 5%). The effective detection of internal cracks in PBX is of great significance for structural integrity assessment and safety reliability evaluation. Ultrasonic phased array detection and imaging methods show great advantages and potential in the detection of crack defects. But acoustic test results indicate that PBX has unique characteristics with low longitudinal wave velocity (~3000 m·s -1 ) and strong attenuation (attenuation coefficient~400 dB·m -1 for 2.5 MHz ultrasound). When the defect is imaged by traditional ultrasonic TFM method, the structural noises at the boundaries between particles lead to low signal-to-noise ratio (SNR) in the FMC signals and strong background noise in reconstructed image, which will bring in interference for the detect of cracks. To realize the high SNR imaging of crack defects in PBX, an ultrasonic imaging algorithm based on baseband nonlinear synthetic focusing (BB-NSF) is proposed. By utilizing the spatial coherence of the received signals in full matrix capture (FMC) data, the pixel intensity at defect position could be enhanced while the background noise could be drastically weakened. The delay rule of the algorithm is modified according to the characteristics of PBX surface configuration. In this way, the high SNR imaging of crack defects with different orientations of PBX surface configuration is realized, and the quality of the reconstructed images is compared and evaluated quantitatively. Meanwhile, the base band transformation in calculation process optimization could significantly release calculation burden and increase imaging efficiency. Experimental results show that the proposed algorithm could effectively suppress background noises and significantly improve detection capability for PBX cracks. The effective suppression to background noise makes the defect more highlighting and being easily distinguished. For BB-NSF algorithm, spatial coherence coefficient p is the crucial parameter used for dynamic regulation of SNR of reconstructed image. When p value is more than 2.0, the SNR of the ultrasonic reconstructed image of PBX crack defect is improved by more than 10 dB compared with the traditional linear synthetic focusing imaging. With the increase of p value, the SNR is further improved, while the calculation efficiency for a single image is almost kept stable. Moreover, the increase of SNR to some extent improves the far-field detect capability. Besides, with BB-NSF algorithm, flexible transducers inhibits different imaging characteristics of for cracks with different orientations and depths in curved PBX specimens. For defects with large orientation angle and buried depth, the tip, root and shape of cracks can be completely presented. For defects with small orientation angle and buried depth, part of shape and contour features will be missing. In conclusion, BB-NSF algorithm shows the advantage of high SNR and calculation efficiency in imaging PBX cracks, and inhibits great application prospect in imaging internal defects of other strongly attenuated composites.
physics, multidisciplinary