A Mixed Conduction Mode Controlled Bridgeless Boost PFC Converter and Its Mission Profile Based Reliability Analysis

Zhengge Chen,Jianping Xu,Pooya Davari,Huai Wang
DOI: https://doi.org/10.1109/tpel.2022.3153558
IF: 5.967
2022-01-01
IEEE Transactions on Power Electronics
Abstract:Given the telecom base transceiver station (BTS) load mission profiles, a mixed conduction mode (MCM) control for a bridgeless boost PFC converter (IPOS boost) is proposed to mainly improve its power factor and reduce the input current total harmonic distortion (THD<span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="5.814ex" height="1.676ex" style="vertical-align: -0.671ex;" viewBox="0 -432.6 2503.1 721.6" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"><g transform="translate(0,-150)"> <use transform="scale(0.707)" xlink:href="#MJMATHI-6D" x="0" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMATHI-61" x="878" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMATHI-74" x="1408" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMATHI-68" x="1769" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMATHI-69" x="2346" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMATHI-74" x="2691" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMATHI-69" x="3053" y="0"></use></g></g></svg></span>) in the light-load conditions. The principle of the MCM control and the efficiency analysis are introduced. Then, the experimental verification is performed to show the control effectiveness and performance improvements. Furthermore, a mission profile-based reliability assessment for the PFC converter is presented to analyze the IPOS boost under the classical average current (AVC) control and the proposed MCM control, along with its conventional boost counterpart under the AVC control. Considering the measured efficiency data and BTS typical mission profiles in a rural area, the analysis results indicate that given 20 years of operation, the accumulated failure of the IPOS boost under the AVC controls is 0.27%, and is further decreased to 0.24% by just the software update with the proposed MCM control. By contrast, the accumulated failure of the conventional boost counterpart under the AVC control is 2.06%, much higher than the IPOS boost.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-6D" d="M21 287Q22 293 24 303T36 341T56 388T88 425T132 442T175 435T205 417T221 395T229 376L231 369Q231 367 232 367L243 378Q303 442 384 442Q401 442 415 440T441 433T460 423T475 411T485 398T493 385T497 373T500 364T502 357L510 367Q573 442 659 442Q713 442 746 415T780 336Q780 285 742 178T704 50Q705 36 709 31T724 26Q752 26 776 56T815 138Q818 149 821 151T837 153Q857 153 857 145Q857 144 853 130Q845 101 831 73T785 17T716 -10Q669 -10 648 17T627 73Q627 92 663 193T700 345Q700 404 656 404H651Q565 404 506 303L499 291L466 157Q433 26 428 16Q415 -11 385 -11Q372 -11 364 -4T353 8T350 18Q350 29 384 161L420 307Q423 322 423 345Q423 404 379 404H374Q288 404 229 303L222 291L189 157Q156 26 151 16Q138 -11 108 -11Q95 -11 87 -5T76 7T74 17Q74 30 112 181Q151 335 151 342Q154 357 154 369Q154 405 129 405Q107 405 92 377T69 316T57 280Q55 278 41 278H27Q21 284 21 287Z"></path><path stroke-width="1" id="MJMATHI-61" d="M33 157Q33 258 109 349T280 441Q331 441 370 392Q386 422 416 422Q429 422 439 414T449 394Q449 381 412 234T374 68Q374 43 381 35T402 26Q411 27 422 35Q443 55 463 131Q469 151 473 152Q475 153 483 153H487Q506 153 506 144Q506 138 501 117T481 63T449 13Q436 0 417 -8Q409 -10 393 -10Q359 -10 336 5T306 36L300 51Q299 52 296 50Q294 48 292 46Q233 -10 172 -10Q117 -10 75 30T33 157ZM351 328Q351 334 346 350T323 385T277 405Q242 405 210 374T160 293Q131 214 119 129Q119 126 119 118T118 106Q118 61 136 44T179 26Q217 26 254 59T298 110Q300 114 325 217T351 328Z"></path><path stroke-width="1" id="MJMATHI-74" d="M26 385Q19 392 19 395Q19 399 22 411T27 425Q29 430 36 430T87 431H140L159 511Q162 522 166 540T173 566T179 586T187 603T197 615T211 624T229 626Q247 625 254 615T261 596Q261 589 252 549T232 470L222 433Q222 431 272 431H323Q330 424 330 420Q330 398 317 385H210L174 240Q135 80 135 68Q135 26 162 26Q197 26 230 60T283 144Q285 150 288 151T303 153H307Q322 153 322 145Q322 142 319 133Q314 117 301 95T267 48T216 6T155 -11Q125 -11 98 4T59 56Q57 64 57 83V101L92 241Q127 382 128 383Q128 385 77 385H26Z"></path><path stroke-width="1" id="MJMATHI-68" d="M137 683Q138 683 209 688T282 694Q294 694 294 685Q294 674 258 534Q220 386 220 383Q220 381 227 388Q288 442 357 442Q411 442 444 415T478 336Q478 285 440 178T402 50Q403 36 407 31T422 26Q450 26 474 56T513 138Q516 149 519 151T535 153Q555 153 555 145Q555 144 551 130Q535 71 500 33Q466 -10 419 -10H414Q367 -10 346 17T325 74Q325 90 361 192T398 345Q398 404 354 404H349Q266 404 205 306L198 293L164 158Q132 28 127 16Q114 -11 83 -11Q69 -11 59 -2T48 16Q48 30 121 320L195 616Q195 629 188 632T149 637H128Q122 643 122 645T124 664Q129 683 137 683Z"></path><path stroke-width="1" id="MJMATHI-69" d="M184 600Q184 624 203 642T247 661Q265 661 277 649T290 619Q290 596 270 577T226 557Q211 557 198 567T184 600ZM21 287Q21 295 30 318T54 369T98 420T158 442Q197 442 223 419T250 357Q250 340 236 301T196 196T154 83Q149 61 149 51Q149 26 166 26Q175 26 185 29T208 43T235 78T260 137Q263 149 265 151T282 153Q302 153 302 143Q302 135 293 112T268 61T223 11T161 -11Q129 -11 102 10T74 74Q74 91 79 106T122 220Q160 321 166 341T173 380Q173 404 156 404H154Q124 404 99 371T61 287Q60 286 59 284T58 281T56 279T53 278T49 278T41 278H27Q21 284 21 287Z"></path></defs></svg>
engineering, electrical & electronic
What problem does this paper attempt to address?