The biomechanical influence of transtibial Bone-Anchored limbs during walking
Amanda L. Vinson,Nicholas W. Vandenberg,Mohamed E. Awad,Cory L. Christiansen,Jason W. Stoneback,Brecca M. M. Gaffney
DOI: https://doi.org/10.1016/j.jbiomech.2024.112098
IF: 2.4
2024-04-18
Journal of Biomechanics
Abstract:Individuals with unilateral transtibial amputation (TTA) using socket prostheses demonstrate asymmetric joint biomechanics during walking, which increases the risk of secondary comorbidities (e.g., low back pain (LBP), osteoarthritis (OA)). Bone-anchored limbs are an alternative to socket prostheses, yet it remains unknown how they influence multi-joint loading. Our objective was to determine the influence of bone-anchored limb use on multi-joint biomechanics during walking. Motion capture data (kinematics, ground reaction forces) were collected during overground walking from ten participants with unilateral TTA prior to (using socket prostheses) and 12-months after bone-anchored limb implantation. Within this year, each participant completed a rehabilitation protocol that guided progression of loading based on patient pain response and optimized biomechanics. Musculoskeletal models were developed at each testing timepoint (baseline or 12-months after implantation) and used to calculate joint kinematics, internal joint moments, and joint reaction forces (JRFs). Analyses were performed during three stance periods on each limb. The between-limb normalized symmetry index (NSI) was calculated for joint moments and JRF impulses. Discrete (range of motion (ROM), impulse NSI) dependent variables were compared before and after implantation using paired t -tests with Bonferroni-Holm corrections while continuous (ensemble averages of kinematics, moments, JRFs) were compared using statistical parametric mapping ( p < 0.05). When using a bone-anchored limb, frontal plane pelvic (residual: pre = 9.6 ± 3.3°, post = 6.3 ± 2.5°, p = 0.004; intact: pre = 10.2 ± 3.9°, post = 7.9 ± 2.6°, p = 0.006) and lumbar (residual: pre = 15.9 ± 7.0°, post = 10.6 ± 2.5°, p = 0.024, intact: pre = 17.1 ± 7.0°, post = 11.4 ± 2.8°, p = 0.014) ROM was reduced compared to socket prosthesis use. The intact limb hip extension moment impulse increased (pre = -11.0 ± 3.6 Nm*s/kg, post = -16.5 ± 4.4 Nm*s/kg, p = 0.005) and sagittal plane hip moment impulse symmetry improved (flexion: pre = 23.1 ± 16.0 %, post = -3.9 ± 19.5 %, p = 0.004, extension: pre = 29.2 ± 20.3 %, post = 8.7 ± 22.9 %, p = 0.049). Residual limb knee extension moment impulse decreased compared to baseline (pre = 15.7 ± 10.8 Nm*s/kg, post = 7.8 ± 3.9 Nm*s/kg, p = 0.030). These results indicate that bone-anchored limb implantation alters multi-joint biomechanics, which may impact LBP or OA risk factors in the TTA population longitudinally.
engineering, biomedical,biophysics