Rapid detection of Staphylococcus aureus in blood culture samples using human IgG-based lateral flow assay

Arpasiri Srisrattakarn,Nicha Charoensri,Jeerati Prompipak,Wajeeorn Ouancharee,Bhanubong Saiboonjan,Patcharaporn Tippayawat,Aroonwadee Chanawong,Lumyai Wonglakorn,Ekgarak Kanwattanee,Sirikan Piyapatthanakul,Thitimar Masmalai,Anisara Ariyapim,Rinjong Promson Kendal,Aroonlug Lulitanond
DOI: https://doi.org/10.1128/spectrum.03046-23
IF: 3.7
2024-01-18
Microbiology Spectrum
Abstract:ABSTRACT Staphylococcus aureus is one of the most common pathogens. The conventional workflow for identifying this organism is time-consuming and takes up to several days. Therefore, we developed a colloidal gold-based lateral flow immunoassay (LFIA) using human IgG as a conjugated antibody to detect S. aureus . One hundred and thirty-eight clinical isolates, including 79 S . aureus and 59 non- S . aureus were spiked in blood samples, and incubated at 37°C for 24 h. The bacterial antigens were simply extracted before being tested by the developed LFIA strips. The results were read by the naked eye within 15 min. Conventional PCR was used as a reference method. The sensitivity and specificity of the developed LFIA were 100% (95% CI: 94.2%–100.0% and 92.4%–100.0%, respectively) in spiked blood culture samples. The detection limits of the LFIA for the purified protein A and bacterial colonies were 10 −3 μg/mL and 10 7 CFU/mL, respectively. The performance of the LFIA testing in 221 bacterial colony isolates and 118 positive blood culture bottles from three hospitals by their medical technologists showed 98.1% (95% CI: 94.1%–99.5%) and 89.7% (95% CI: 79.3%–95.4%) sensitivity, respectively. The LFIA is a quick, easy, and sensitive method for detecting S. aureus without expensive equipment. It might have the potential for early diagnosis of routine service in low-resource laboratories, leading to a rapid and effective treatment. IMPORTANCE In this study, we modified our previously developed lateral flow immunoassay (LFIA) test for the detection of Staphylococcus aureus by using an in-house human IgG as a conjugated antibody instead of the specific commercial antibody. It gave comparable results to the former developed-LFIA test and helped cost reduction.
microbiology
What problem does this paper attempt to address?
### Problems the Paper Aims to Solve This paper aims to develop a colloidal gold-based lateral flow immunoassay (LFIA) method for the rapid detection of *Staphylococcus aureus* in blood culture samples. Traditional methods for identifying *Staphylococcus aureus* are time-consuming, often taking several days. Therefore, the researchers developed a colloidal gold lateral flow immunoassay (LFIA) based on human IgG antibodies to achieve rapid, simple, and sensitive detection. Specifically, the goals of this study include: 1. **Developing the LFIA method**: Using human IgG as the binding antibody to replace commercial specific antibodies, thereby reducing detection costs. 2. **Validating LFIA performance**: Evaluating the sensitivity and specificity of the LFIA in clinical samples and comparing it with traditional PCR methods. 3. **Assessing practical application**: Testing the effectiveness of the LFIA method in real laboratory environments in 3 hospitals. Through these objectives, the study aims to provide a rapid, low-cost, and effective detection method for early diagnosis in low-resource settings, thereby promoting timely treatment and reducing disease progression.