An Adenosylcobalamin Specific Whole‐Cell Biosensor

Juan José Quispe Haro,Seraphine V. Wegner
DOI: https://doi.org/10.1002/adhm.202300835
IF: 10
2023-04-19
Advanced Healthcare Materials
Abstract:Vitamin B12 (cobalamin) is essential for human health and its deficiency results in anemia and neurological damage. Vitamin B12 exists in different forms with various bioactivity but most sensors are unable to discriminate between them. Here, we report a whole‐cell agglutination assay that is specific for adenosylcobalamin (AboB12), which is one of two bioactive forms. This biosensor consists of E. coli that express the AdoB12 specific binding domain of CarH at their surface. In the presence of AdoB12, CarH forms tetramers, which leads to specific bacterial cell‐cell adhesions and agglutination. These CarH tetramers disassemble upon green light illumination such that reversion of the bacterial aggregation can serve as internal quality control. The agglutination assay has a detection limit of 500 nм AdoB12, works protein poor biofluids such as urine, and has high specificity to AdoB12 over other forms of vitamin B12 as also demonstrated with commercially available supplements. This work is a proof of concept for a cheap and easy‐to‐readout AdoB12 sensor that could be implemented at the point‐of‐care to monitor high‐dose vitamin B12 supplementation. This article is protected by copyright. All rights reserved
nanoscience & nanotechnology,engineering, biomedical,materials science, biomaterials