Diagnostic power of relative sit-to-stand muscle power, grip strength, and gait speed for identifying a history of recurrent falls and fractures in older adults

Duque, Gustavo
DOI: https://doi.org/10.1007/s41999-023-00778-x
2023-04-15
European Geriatric Medicine
Abstract:To compare the diagnostic value of relative sit-to-stand muscle power with grip strength or gait speed for identifying a history of adverse outcomes in older adults. When compared to grip strength or gait speed, relative sit-to-stand muscle power offered slightly (but not statistically) higher diagnostic power for identifying a history of recurrent falls and fractures in older adults. However, all tests showed low diagnostic power (AUC < 0.7). Further prospective cohort studies should examine the diagnostic power of relative sit-to-stand muscle power for incident falls and fractures. This information is important to evaluate if this test offers true clinical value (and benefit over grip strength or gait speed) for identifying these adverse outcomes. To compare the diagnostic value of relative sit-to-stand muscle power with grip strength or gait speed for identifying a history of recurrent falls and fractures in older adults. Data from an outpatient clinic included anthropometry (height/weight), bone density, 5 times sit-to-stand time (stopwatch and standardized chair), grip strength (hydraulic dynamometer), and gait speed (4 m). Relative sit-to-stand muscle power (W.kg−1, normalised to body mass) was calculated using a validated equation. Outcomes of falls (past 1 year) and fractures (past 5 years) were self-reported and verified by medical records wherever possible. Binary logistic regression considering for potential confounders (age, sex, BMI, Charlson comorbidity index, femoral neck bone density) and receiver operating characteristics (ROC) curves were used in statistical analysis. 508 community-dwelling older adults (median age: 78 years, interquartile range: 72, 83, 75.2% women) were included. Compared to greater relative sit-to-stand muscle power (1.62–3.78W.kg−1 for women; 2.03–3.90W.kg−1 for men), those with extremely low relative sit-to-stand muscle power were 2.35 (95% CI 1.54, 3.60, p < 0.001) and 2.41 (95% CI 1.25, 4.65, p = 0.009) times more likely to experience recurrent falls and fractures, respectively, in fully adjusted model. Compared to grip strength or gait speed, relative sit-to-stand muscle power showed the highest area under the ROC curve for identifying recurrent falls (AUC: 0.64) and fractures (AUC: 0.62). All tests showed low diagnostic power (AUC: < 0.7). Relative sit-to-stand muscle power performed slightly (but not statistically) better than grip strength or gait speed for identifying a history of recurrent falls and fractures in older adults. However, all tests showed low diagnostic power.
geriatrics & gerontology,gerontology
What problem does this paper attempt to address?