Effects of Contact Loss at Electrolyte/Negative Electrode Interface on Current Density Distribution in Solid-State Batteries

Evans Leshinka Molel,John A. Lewis,Stephanie Elizabeth Sandoval,Douglas Lars Nelson,Matthew T. Mcdowell,Thomas F. Fuller
DOI: https://doi.org/10.1149/1945-7111/ad7e93
IF: 3.9
2024-09-26
Journal of The Electrochemical Society
Abstract:Cyclic volume changes and non-uniform electrodeposition/stripping, among other cycling-induced chemo-mechanical degradation of lithium metal and lithium-alloy solid state batteries, lead to contact loss between the anode and the solid electrolyte separator. Operando experiments have shown accelerated short-circuiting behavior due to contact loss in "anode-free" solid-state batteries. Simulations have shown the relationship between active area fraction and the ratio of effective conductivities in regular-shape active area configurations. Through modeling experiments using imputed active contact area of lithium-metal negative electrode batteries, we quantify the effects of this contact loss. Specifically, we (1) quantify the interfacial resistance due to this contact loss, (2) show non-uniform local current density distribution such that evaluation of what area fraction has current exceeding critical current densities is possible, and (3) show non-uniform reaction distribution at the positive electrode. This work sheds light on the tradeoffs in the design of solid state batteries within the context of contact loss.
electrochemistry,materials science, coatings & films