Analysis of Unsteady Heat Transfer in the Pre-Cooling Process of 300 m3 Liquid Hydrogen Tank

Qiang Chen,Xiaoping Zhang,Xiaojing Yang,Lufeng Yang,Tianxiang Wang,Gang Lei
DOI: https://doi.org/10.3390/pr11030787
IF: 3.5
2023-03-08
Processes
Abstract:A mathematical model for the pre-cooling process was established to solve the problems of the long pre-cooling time and uncertain parameters of cryogenic propellant tanks. The pre-cooling parameters of a 300 m3 liquid hydrogen tank at several cooling rates were calculated and analyzed. The results show that the liquid hydrogen flow required to pre-cool the gas in the tank, tank wall, accessories, and interlayer thermal insulation materials increases first and then decreases and that the liquid hydrogen flow needed to offset the heat leakage gradually increases with the temperature reduction. When the average cooling rate rose from 0.1 K/min to 1 K/min, the pre-cooling time was shortened from 2730 min to 273 min, and the consumption of liquid hydrogen decreased from 2115 kg to 2091 kg. Among the various heat loads, the inner tank wall and accessories consumed the most significant proportion of liquid hydrogen, accounting for 87.84% to 88.61%. The cooling capacity was derived from the liquid hydrogen's evaporation and the cryogenic hydrogen gas's heating process, of which the liquid hydrogen accounted for 23.00%. Considering the principle of safe operation, it is recommended that stepped pre-cooling in two or three stages based on the maximum cooling rate is conducted.
engineering, chemical
What problem does this paper attempt to address?
The problems that this paper attempts to solve are the long - pre - cooling time and parameter uncertainty in the pre - cooling process of large - scale liquid hydrogen storage tanks. Specifically, the author established a mathematical model to analyze the unsteady - state heat transfer during the pre - cooling process of a 300 - cubic - meter liquid hydrogen storage tank, aiming to optimize the pre - cooling process, reduce the pre - cooling time and liquid hydrogen consumption, and ensure the safety of operation at the same time. ### Background of the Paper - **Research Object**: 300 - cubic - meter liquid hydrogen storage tank. - **Problem**: There are problems of long - pre - cooling time and parameter uncertainty in the pre - cooling process of liquid hydrogen storage tanks, which affect the efficiency and safety of tank use. - **Objective**: By establishing a mathematical model, analyze the pre - cooling parameters at different cooling rates, optimize the pre - cooling process, shorten the pre - cooling time, reduce liquid hydrogen consumption, and ensure safe operation. ### Main Content 1. **Introduction**: - Compared with traditional propellants, liquid hydrogen/oxygen propellants have the advantages of high specific impulse, non - toxicity, and non - pollution, and are widely used in new - type rockets. - Liquid hydrogen storage tanks require good heat insulation performance. In the early days, multi - layer or perlite vacuum heat insulation was mainly used, and in recent years, new materials such as aerogels and glass microspheres have been applied. - When the storage tank is directly filled with cryogenic propellants, large thermal stresses will be generated due to the sudden change in temperature, so pre - cooling is required. - The safety of the pre - cooling process is the primary consideration factor, but at present, relevant technical standards are lacking. 2. **Establishment of the Pre - cooling Model**: - **Heat Transfer Analysis**: Three heat transfer forms, namely convection, conduction, and radiation, are involved in the pre - cooling process. - **Model Assumptions**: It is assumed that the pre - cooling liquid and gas temperature distributions are uniform, the inner wall surface and the fluid medium have the same temperature, the pressure is constant, tangential heat transfer is ignored, and the liquid hydrogen volume is ignored. - **Mathematical Model**: Based on the principle of energy conservation, a mathematical model of the pre - cooling process was established, including the cooling gas, inner wall and accessories, heat - insulating materials, and the cooling capacity required to offset heat leakage. 3. **Parameter Calculation Process**: - The actual unsteady - state pre - cooling process is simplified into a steady - state process within each time unit, and the consumption of the pre - cooling medium and the temperature change trend are obtained through iterative calculation. 4. **Results and Discussion**: - **Liquid Hydrogen Flow Rate at Different Cooling Rates**: As the temperature drops, the liquid hydrogen flow rate first increases and then decreases, and the flow rate required to offset heat leakage always increases. - **Pre - cooling Process Parameters**: The greater the average cooling rate, the shorter the pre - cooling time and the less the liquid hydrogen consumption. The proportion of liquid hydrogen consumed by the inner wall and accessories is the highest, accounting for 87.84% to 88.61%. ### Conclusion - By establishing a mathematical model, the pre - cooling process of a 300 - cubic - meter liquid hydrogen storage tank at different cooling rates has been successfully analyzed, providing theoretical support for the selection of actual pre - cooling parameters. - It is recommended to adopt the phased pre - cooling method to ensure the safety and efficiency of operation. Hope this information is helpful to you! If you have more questions or need further explanation, please feel free to let me know.