Cyanide Molecular Laser-Induced Plasma Spectroscopy

C G Parigger,C M Helstern
DOI: https://doi.org/10.1088/1742-6596/2439/1/012003
2023-02-11
Journal of Physics: Conference Series
Abstract:This work communicates recent measurements of CN in laser-induced plasma. The main goals and objectives comprise (a) exploring CN measurement using optical emission spectroscopy in optical breakdown plasma; (b) determining the effects of laser-induced shockwave for time delays of the order of 1 μs; (c) evaluating the spatial distribution of CN signals; (d) inferring CN temperature distribution; and (e) associating recorded shadowgraphs with laser-spectroscopy results. Q-switched, 150 mJ, 6 ns pulsed Nd:YAG laser radiation at the fundamental wavelength of 1064 nm is used to generate micro-plasma in a gas mixture with ultra-high purity nitrogen and research grade carbon dioxide. The CO 2 to N 2 molar ratio is 1 to 1 for the gaseous mixture near atmospheric pressure flowing through the chamber. Optical emissions are dispersed by a 0.64-m Czerny-Turner spectrometer and an intensified charge-coupled device records the data along the wavelength and slit dimensions. The analysis utilizes Abel integral inversion techniques for determination of spatiotemporal profiles.
What problem does this paper attempt to address?