Enzyme free direct detection of histamine in peanuts using novel γ-MnOOH-W3O10 nanostructures modified electrode

Amisha Kushwaha,Gajendar Singh,Umesh Kumar Gaur,Manu Sharma
DOI: https://doi.org/10.1039/d2nj05255e
IF: 3.3
2023-01-08
New Journal of Chemistry
Abstract:Direct electrochemical detection of histamine (HS) in peanuts has been carried out using MW@GCE. MW (MnO4W) has been prepared through hydrothermal treatment using γ-MnOOH and W3O10 nanostructures. Synthesized γ-MnOOH (MNO), W3O10 (WO) and MnO4W (MW) nanostructures have been characterized by XRD, FE-SEM, HR-TEM, XPS and SECM techniques for structural, morphological, and electrochemical properties. MW@GCE was superior electrode in comparison with MNO@GCE, and WO@GCE confirmed by CV, Mott-Schottky, and impedance analysis. MW@GCE sensor limit of detection was recorded as 5.817 nM and 3.7 nM for DPV and amperometric analysis. HS sensitivity was also recoded as 233.99 A/M-cm2 and 664.20 A/M-cm2 for DPV (0.1 – 0.16 M) and amperometric. Further, HS detection in peanuts extract was done, ~ 0.16 M (average amount) of HS was quantified based on the 18 concentrations. The usual spiking approach was also used for HS validation in peanuts, with recoveries ranging from 105.3 to 106.2% and relative standard deviations ranging from 2.41 to 3.19%. The MW@GCE electrode's robustness has also been explored in terms of long-term storage, repeatability, and reproducibility study. Because of the direct detection capabilities of HS in peanuts and its resilience, this sensing system is useful for food and pharmaceutical sample analysis.
chemistry, multidisciplinary
What problem does this paper attempt to address?