A Multienzyme Reaction-Mediated Electrochemical Biosensor for Sensitive Detection of Organophosphorus Pesticides

Chengzhen Ji,Xuemei Tang,Ruiming Wen,Chengdong Xu,Jing Wei,Bingjun Han,Long Wu
DOI: https://doi.org/10.3390/bios14020062
2024-01-25
Biosensors
Abstract:Ethephon (ETH), a commonly employed growth regulator, poses potential health risks due to its residue in fruits and vegetables, leading to both acute and subchronic toxicity. However, the detection accuracy of ETH is compromised by the color effects of the samples during the detection process. In this work, a multienzyme reaction-mediated electrochemical biosensor (MRMEC) was developed for the sensitive, rapid, and color-interference-resistant determination of ETH. Nanozymes Fe3O4@Au–Pt and graphene nanocomplexes (GN–Au NPs) were prepared as catalysts and signal amplifiers for MRMEC. Acetylcholinesterase (AChE), acetylcholine (ACh), and choline oxidase (CHOx) form a cascade enzyme reaction to produce H2O2 in an electrolytic cell. Fe3O4@Au–Pt has excellent peroxidase-like activity and can catalyze the oxidation of 3,3′,5,5′-tetramethvlbenzidine (TMB) in the presence of H2O2, resulting in a decrease in the characteristic peak current of TMB. Based on the inhibitory effect of ETH on AChE, the differential pulse voltammetry (DPV) current signal of TMB was used to detect ETH, offering the limit of detection (LOD) of 2.01 nmol L−1. The MRMEC method effectively analyzed ETH levels in mangoes, showing satisfactory precision (coefficient of variations, 2.88–15.97%) and recovery rate (92.18–110.72%). This biosensor holds promise for detecting various organophosphorus pesticides in food samples.
chemistry, analytical,nanoscience & nanotechnology,instruments & instrumentation
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to develop an electrochemical biosensor that is fast, sensitive and free from color interference for the detection of ethephon (ETH), an organophosphorus pesticide residue in fruits and vegetables. Specifically, the research aims to overcome the problems of high background interference, high cost and large instrument volume in traditional detection methods such as gas chromatography - mass spectrometry (GC - MS) and high - performance liquid chromatography - mass spectrometry (HPLC - MS). ### Research Background Ethephon (ETH) is a growth regulator widely used in fruits and vegetables. Although it can significantly improve the quality and yield of crops, its residues may cause acute or sub - chronic toxicity to human health. Traditional detection methods such as gas chromatography - mass spectrometry (GC - MS) and high - performance liquid chromatography - mass spectrometry (HPLC - MS), although highly sensitive, also have the disadvantages of high background interference, high cost and large instrument volume. ### Solution To overcome these problems, researchers have developed an electrochemical biosensor mediated by multi - enzyme reaction (MRMEC). This sensor uses nano - enzymes (Fe₃O₄@Au–Pt and graphene nanocomposite GN–Au NPs) as catalysts and signal amplifiers, and generates hydrogen peroxide (H₂O₂) through a cascade enzyme reaction (acetylcholinesterase AChE, acetylcholine ACh and choline oxidase CHOx). Fe₃O₄@Au–Pt has peroxidase - like activity and can catalyze the oxidation of 3,3′,5,5′ - tetramethylbenzidine (TMB) in the presence of H₂O₂, resulting in a decrease in the characteristic peak current of TMB. Based on the inhibitory effect of ETH on AChE, the detection of ETH is achieved by detecting the current signal of TMB by differential pulse voltammetry (DPV). ### Key Innovation Points 1. **Avoiding color interference**: Electrochemical detection technology replaces the single colorimetric method, which not only improves sensitivity but also overcomes the interference of sample color. 2. **High sensitivity**: The limit of detection (LOD) of this sensor is 2.01 nmol L⁻¹. 3. **Verification in practical applications**: This method has been successfully applied to the detection of ETH residues in mangoes, showing satisfactory precision (coefficient of variation 2.88%–15.97%) and recovery rate (92.18%–110.72%). In conclusion, this study proposes a novel, fast, sensitive and easy - to - operate method, which is suitable for the detection of various organophosphorus pesticides in food samples.