The Influencing Factors of Disposable Acetylcholinesterase Biosensor for in Situ Detection of Organophosphorus Pesticide
Xiaowen Xu,Xiaohao Wang,Fei Tang,Zhaoying Zhou
2006-01-01
Rare Metal Materials and Engineering
Abstract:An amperometric biosensor based on acetylcholinesterase (AChE) is assembled by simple adsorption of the AChE on 7,7,8,8-tetracyanoquinodimethane (TCNQ) modified screen-printed electrodes. This biosensor is used to detect the inhibitory effect of organophosphorus pesticides on AChE activity. The detection of organophosphorus pesticides is done with acetylthiocholine chloride (ATCh) as substrate. In order to obtain the optimized response to substrate, the influencing factors of the biosensor are investigated, including temperature, pH, incubation time, substrate concentration and AChE concentration. The measurements were performed after inhibition by immersing the enzyme electrode into the parathion methyl solution. Under the optimized conditions, that is, 500 U/ml AChE concentration, pH 7.2, 10 min incubation time, 2 mmol/L substrate concentration and temperature of 37 degrees C, from 5 x 10(-8) mol/L to 5 x 10(-5) mol/L is close to linear (regression equation: y(%)=124.055+15.7991gx, R-2=0.99644), which corresponds to 8.7%similar to 56.1% AChE inhibition. With the optimized conditions, the lowest detectable amount of parathion methyl is 13 x 10(-9).