Proposal and energy/exergy analysis of a novel cryogenic air separation configuration for the production of neon and argon

Mehran Saedi,Mehdi Mehrpooya,Mostafa Delpisheh,Andrew Zaitsev
DOI: https://doi.org/10.1007/s11696-022-02396-6
IF: 2.146
2022-08-06
Chemical Papers
Abstract:Cryogenic air separation has efficaciously been implemented to provision oxygen, nitrogen, argon, neon, and other valuable products for a wide range of applications. Herein, the present study investigates neon and argon recovery from a novel four-column air separation unit. The system is appraised through thermodynamic and sensitivity analyses. The system produces a crude neon product with a small fraction (approximately 0.08), as well as argon and oxygen with a purity of 0.93 and 0.995, respectively. The energy analysis indicated an overall specific energy consumption of 0.057 kWh/kg. The exergy analysis revealed that the air coolers had the highest exergy destruction at a share of 59%, while the columns had the least at 4%. Also, the pumps, expanders, and valves, respectively, had the highest exergy efficiencies. The sensitivity analysis signposted that the temperature and pressure of the inlet to the low-pressure column in tandem with the reflux ratio of argon and neon column have the highest influence on system performance. Feeding on 100 kg/s of air, the system produces 82.87 kg/s of nitrogen, 16.81 kg/s of oxygen, 0.018 kg/s of neon, and 0.302 kg/s of argon.
chemistry, multidisciplinary
What problem does this paper attempt to address?