In Situ High-Temperature TEM Observation of Inconel Corrosion by Molten Chloride Salts with N2, O2, or H2O

Prachi Pragnya,Daniel Gall,Robert Hull
DOI: https://doi.org/10.1149/1945-7111/ac8376
IF: 3.9
2022-07-24
Journal of The Electrochemical Society
Abstract:In situ TEM is used to understand corrosion of Inconel-625 by chloride salts (MgCl2 − NaCl − KCl) at 500-800°C in 1.0 atm inert N2 or pure O2, or hydrated salts. The isothermal corrosion rate R in inert N2 increases from 203 ± 30 μm year-1 at 700°C to 463 ± 30 μm year-1 at 800°C. An oxygen ambient causes a six-fold increase to R = 1261 ± 170 μm year-1. Salt hydration dramatically accelerates corrosion to R > 3×105 μm year-. These isothermal corrosion rates indicate that the molten chloride corrosion is significantly accelerated by salt hydration at temperatures above 600°C. To reduce the rate of corrosion it is important to both avoid incorporation of H2O into the system and ensure proper flushing before increasing the temperature beyond 600°C. In addition, steps should be taken to tailor chloride melt compositions that has low solubility for HCl and O2. All of our corroded samples exhibit passive-protective oxide layers of Cr, Mg, and Ni. In addition, distinct volatile compounds are detected. To minimize corrosion formation of volatile by-products should be avoided.
electrochemistry,materials science, coatings & films
What problem does this paper attempt to address?