Carbon monoxide gas sensor based on Co/Ni-MOF-74 coated no-core-fiber Michelson interferometer

Juncheng Zhou,Xinyue Huang,Wenlin Feng
DOI: https://doi.org/10.1088/1402-4896/aca848
2022-12-03
Physica Scripta
Abstract:A Michelson interferometric carbon monoxide (CO) fiber-optic sensor based on Co/Ni-MOF-74 is proposed and fabricated. The bimetallic-ion-coordination MOFs material Co/Ni-MOF-74 was prepared by solvothermal method. Through XRD and XPS characterizations, the results show that Co/Ni-MOF-74 and Ni-MOF-74 have the same crystal structure. Co/Ni-MOF-74 has a good adsorption effect on CO, and it is integrated into the optical fiber sensing structure for CO detection. In the CO concentration range of 0-35 ppm, the sensitivity and linearity are 0.02235 dB/ppm and 0.99936, respectively. The detection limit of the sensor is about 1.99046 ppm. The presented fiber-optic sensor has excellent selectivity, resistance to temperature interference and good time stability, and it is expected to be applied to the detection of trace CO.
physics, multidisciplinary
What problem does this paper attempt to address?