Preparation of a metal organic framework (MOF)-based monolithic column for the solid-phase extraction (SPE) of diosmetin from traditional Chinese medicine with determination by high-performance liquid chromatography (HPLC)

Shan Wang,Yamei Han,Jiangwei Chen,Ligai Bai,Hongyuan Yan,Haiyan Liu
DOI: https://doi.org/10.1080/10739149.2022.2120894
2022-09-15
Abstract:A metal organic framework (MOF)-based monolithic column was prepared by in situ polymerization using modified MIL-101-NH 2 and glycidyl methacrylate (GMA) as monomers. The monolithic column was used as a solid phase extraction (SPE) adsorbent for on-line enrichment and preliminary purification of diosmetin in traditional Chinese medicine. After being characterized by scanning electron microscopy (SEM) and nitrogen adsorption-desorption, the advantages of the monolithic column with MIL-101-NH 2 added were reflected in the pore structure and specific surface area. The monolithic column for SPE had a linear relationship from 0.13 μg/mL to 5.0 × 10 2 μg/mL. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.04 μg/mL and 0.13 μg/mL, respectively. The recovery was from 96% to 104%, and the intra-day and inter-day relative standard deviations (RSDs) were below 1.1%. This method was suitable for the determination of diosmetin in complex samples.
chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?