A high gradient and strength bioseparator with nano-sized immunomagnetic particles for specific separation and efficient concentration of E. coli O157:H7

Jianhan Lin,Min Li,Yanbin Li,Qi Chen
DOI: https://doi.org/10.1016/j.jmmm.2014.11.039
IF: 3.097
2015-03-01
Journal of Magnetism and Magnetic Materials
Abstract:Sample pretreatment is a key to rapid screening of pathogens for prevention and control of foodborne diseases. Magnetic immunoseparation is a specific method based on antibody–antigen reaction to capture the target bacteria and concentrate them in a smaller-volume buffer. The use of nano-sized magnetic particles could improve the separation efficiency of bacteria but require much higher gradient and strength magnetic field. In this study, a strong magnetic bioseparator with a mean field strength of 1.35T and a mean gradient of 90T/m was developed with the use of the 30nm and 180nm magnetic particles to specifically separate and efficiently concentrate foodborne bacterial pathogens using Escherichia coli O157:H7 as a model bacterium. The polyclonal antibodies against E. coli were evaluated using Dot ELISA analysis for their good affinity with the target bacteria and then used to modify the surface of the magnetic nanoparticles by 1-(3-Dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC·HCl) method and streptavidin-biotin binding. The magnetic particle concentrations were optimized to be 40µg/ml and 100µg/ml for the 30nm and 180nm particles, respectively, the immunoreaction time was optimized to be 45min for both sizes of particles, and the separation times were optimized to be 60min and 2min for the 30nm and 180nm particles, respectively. The total magnetic separation time was 2h and 1h for the 30nm and 180nm particles, respectively. The experimental results demonstrated that the bioseparator with the use of either 30nm or 180nm immunomagnetic particles could achieve a separation efficiency of >90% for E. coli O157:H7 at the concentrations ranging from 102 to 105 cfu/ml. No obvious interferences from non-target foodborne pathogens, such as Salmonella Typhimurium and Listeria innocua, were found. For overall consideration of the consuming time, the cost, and the separation efficiency, the 180nm magnetic particles are practical for rapid screening applications; however the 30nm magnetic particles are preferable for specific detection applications. This immunomagnetic bioseparator can be integrated with either conventional culture methods or some rapid detection methods, such as biosensors and PCR, for more sensitive detection of foodborne pathogens.
materials science, multidisciplinary,physics, condensed matter
What problem does this paper attempt to address?