Separating Contributions from Pre-Mobilization and Ground Improvement for Post-Grouted Drilled Shafts

Tayler J. Day,Andrew Z. Boeckmann,J. Erik Loehr
DOI: https://doi.org/10.1061/9780784479087.086
2015-03-17
Abstract:The load-displacement response of drilled shafts has been shown to improve with application of pressurized grout to the shaft tip after construction (post-grouting). The pressurized grout applies a bi-directional force at the shaft tip during grouting, which results in upward movement of the shaft and downward movement of the soil beneath the tip. Displacements resulting from the bi-directional force increase the side resistance that can be mobilized and decrease the tip resistance that can be mobilized for subsequent top-down loading. This re-distribution of resistance, referred to as “pre-mobilization”, results in a “stiffer” load-displacement response to top-down loading compared to a similar ungrouted shaft but results in no change to the ultimate shaft resistance. Post-grouting may also produce an increase in the ultimate tip resistance by improving the ground beneath the shaft tip via mechanisms that include densification, tip enlargement, and grout permeation. A 1-D finite element model with capabilities for predicting the improvement due to pre-mobilization was used isolate contributions from pre-mobilization and ground improvement for load test measurements on similar post-grouted and conventional shafts at a representative site. Back-calculated values for unit tip resistance are compared to quantify the improved performance that can be attributed to pre-mobilization and ground improvement, respectively.
What problem does this paper attempt to address?