Experimental study of electron transpiration cooling with a 2-kW laser heating system

Junhwi Bak,Anuj Rekhy,Christopher Limbach,Richard B. Miles,James Creel
DOI: https://doi.org/10.2514/6.2022-0983
2022-01-03
Abstract:View Video Presentation: https://doi.org/10.2514/6.2022-0983.vid A rapid surface temperature drop is observed on a negatively biased, thermally controlled, thermionic emitter at the initiation of an "ignited mode" plasma in argon and attributed to electron transpiration cooling (ETC). A transient current surge accompanies the observed rapid temperature drop, indicating that the ignited mode eliminates space charge limitations, allowing electrons to freely escape from the heated surface while taking energy away. This appears to be the first direct observation of active surface cooling by ETC, providing experimental confirmation of the method. A 2-kW laser directly irradiates the front surface of the emitter, depositing precision controlled surface heat influx. Two-color pyrometry is implemented to temporally resolve the rapidly varying surface temperature at the point of ignited mode initiation. The observed ETC behavior is qualitatively reproduced with a simplified quasi-1D heat model of the emitter and detailed heat balance on the front surface is studied.
What problem does this paper attempt to address?