Assessing glare. Part 2: Modifying Unified Glare Rating for uniform and non-uniform LED luminaires

Y Yang,M Ronnier Luo,SN Ma
DOI: https://doi.org/10.1177/1477153516642622
2016-04-05
Abstract:This paper proposes a new glare model for assessing discomfort glare caused by LED luminaires having different luminance uniformities. It has been derived from the glare rating data for different groups of LED luminaires representing different degrees of luminance uniformity. In total, 5040 glare ratings were collected. Unified Glare Rating was tested using these data. It was found that Unified Glare Rating under-estimates the glare perception produced by non-uniform luminance glare sources. Furthermore, two modified Unified Glare Rating models proposed by Tashiro et al. and by the present authors were tested. They both performed well when predicting the results for LED luminaires having different luminance uniformities.
construction & building technology,optics
What problem does this paper attempt to address?