PFAS emissions from functional textiles using micro-chamber and thermal desorption coupled to two-dimensional gas chromatography-time of flight mass spectrometry (TD-GC×GC-TOF MS)
Rocio Aranda-Rodriguez,Ariadne Piperakis,Jonathan Grandy,Laura McGregor,Nadin Boegelsack,Hannah Calder,Matthew Edwards,William Papas,Jasper Che,Sam Shields
DOI: https://doi.org/10.1016/j.chroma.2024.465219
2024-08-04
Abstract:Per- and polyfluoroalkyl substances (PFAS), in the polymeric form, have been used extensively in functional textiles, including firefighter's turnout gear (e.g., jackets and pants), where PFAS are applied to confer oil and water resistance. However, growing concerns over the persistence, potential toxicity, and environmental impact of PFAS have prompted a thorough assessment of potential exposure pathways. Here, we report the emission of PFAS from three firefighter turnout gear jackets at 38 °C. Volatile emissions from the three layers (outer layer, moisture barrier, and thermal liner) were collected onto sorbent tubes via dynamic headspace sampling using a micro-scale chamber device kept at 38 °C for one hour. The emission was characterized using thermal desorption (TD) coupled to two-dimensional gas chromatography - time-of-flight mass spectrometry (GC×GC-TOF MS). The enhanced separation capacity of GC×GC was essential due to the high number of compounds present in each sample, especially for the fabrics from used turnout gear jackets. Based on the filtering expressions, including two-dimensional retention time (1tr and 2tr) and PFAS diagnostic fragment ions (m/z 69, 95, and 131), fluorotelomer alcohols (FTOHs) and fluorotelomer acrylates were identified using standards and spectral matching with the NIST database. After conducting a non-targeted tile-based workflow, jackets (both used and unused) and layers were compared, resulting in the identification of the top 15 discriminating features from over 400 chromatographic peaks. Finally, preliminary FTOH emission experiments showed some usage and layers trends that are aligned with those reported using solvent extraction. Highest levels of FTOHs were found in the moisture barrier, followed by the outer layer and the thermal liner. Older jackets emitted higher levels of 8:2 FTOH and 10:2 FTOH than a newer jacket. In contrast, a newer jacket used for one year had emissions containing higher levels of 6:2 FTOH. Investigating routes of exposure and identifying new PFAS targets are critical steps in evaluating the environmental and health impacts of these persistent chemicals.