Abstract:Summary Air-tightness of the concrete lining is a critical factor for a railway tunnel to be operated under partial vacuum. The testing described in this article investigates the influence on air permeability of aggregate composition (sand content, maximum grain size), type of cement, addition of steel fibers, degree of saturation of the concrete, and use of a curing compound. Laboratory testing was performed on samples taken from 18 concrete wall elements representing a range of pumped concrete mixtures. Fresh-concrete properties, compressive strength, and porosity were also measured. This report handles the first 12 concrete mixtures. Evaluation of the remaining testing is still in progress.