Effect of direct solar projected area factor on outdoor thermal comfort evaluation: A case study in Shanghai, China

Zhengrong Li,Xiwen Feng,Xueke Fan,Jingting Sun,Zhaosong Fang
DOI: https://doi.org/10.1016/j.uclim.2021.101033
IF: 6.663
2022-01-01
Urban Climate
Abstract:The outdoor mean radiant temperature (T mrt ) is largely influenced by the direct solar radiation incident on the human body, mainly affected by the projected area factor (f p ). The f p has been calculated by different methods and compared by some studies. However, how the f p quantitatively affects outdoor thermal comfort has rarely been studied. Therefore, this study established sitting, standing, and walking human models to calculate the f p in different solar positions through Monte Carlo ray-tracing technology. A case study has been taken in Shanghai to analyze the effect of the f p on outdoor thermal comfort. The Fanger, Jendritzky, and Underwood models' applicability in Shanghai was compared. The f p of sitting, standing, and walking postures have been obtained, respectively. The results show that more than 0.05 f p difference may cause half of the thermal grade deviation for outdoor thermal comfort evaluation. The f p is more sensitive to solar altitude (β) in three postures than solar azimuth (α). The f p difference from different postures can cause more than half of thermal grade deviation. Fanger's model for sitting posture may cause one thermal grade deviation; Jendritzky's model has acceptable performance for three postures; Underwood's model for sitting and walking postures may result in nearly one thermal grade deviation.
environmental sciences,meteorology & atmospheric sciences