Abstract:Since the column members in buildings deal with both vertical and horizontal loads, appropriated amount of load should be estimated in order to evaluate the fire resistance performance of the columns under loaded condition. However, according to the ISO 834, the international standard for the evaluation of structural members, the fire resistance performance evaluation of column members is only based on the displacement and displacement rate under loaded condition in a standard fire. The purpose of this study is to suggest appropriate axial load ratios for the evaluation of fire resistance performance. The test conducted in this study produced appropriate axial load ratios for different slenderness ratios. They are expected to contribute to more accurate estimation of fire resistance performance and more efficient and cost-effective structural design.