The diagnostic accuracy of specific IgE to Ara h 6 in adults is as good as Ara h 2

R. J. B. Klemans,E. F. Knol,C. A. F. M. Bruijnzeel‐Koomen,A. C. Knulst,C. A. F. M. Bruijnzeel-Koomen
DOI: https://doi.org/10.1111/all.12424
IF: 12.4
2014-05-09
Allergy
Abstract:Specific IgE (sIgE) to Ara h 2 is useful in diagnosing peanut allergy. Our aim was to assess the diagnostic value of sIgE to Ara h 6, another 2S albumin, in an adult population suspected of peanut allergy. Subjects with suspected peanut allergy between 2002 and 2013 were included if a diagnostic double-blind, placebo-controlled food challenge with peanut was performed. sIgE to Ara h 2 and Ara h 6 was measured by ImmunoCAP ISAC 112. Of 107 challenged subjects, 65 had a positive challenge (61%). The discriminative ability of sIgE to Ara h 2 and Ara h 6 was comparable: AUC 0.81 vs. 0.82. Positive predictive value for both tests was 95% using a cutoff value ≥1 ISU/l with poor corresponding sensitivity values (58% for Ara h 2, 62% for Ara h 6), but good specificity values (95% for both tests). In conclusion, the diagnostic value of sIgE to Ara h 6 on population level was as good as sIgE to Ara h 2. On individual level, however, 5% of the subjects showed contradicting results between both tests using a cutoff of 0.3 ISU/l, leading to a risk of misdiagnosis if only one of both tests is used.
immunology,allergy