617 Frictional Vibration of a Flaw Detection Probe Generated in an Evaporator Tube Installed in a Nuclear Power Station : Numerical Simulation

,,,,Takumi INOUE,Yutaka NAKANO,Atsuo SUEOKA,Yukitaka MURAKAMI
DOI: https://doi.org/10.1299/jsmedmc.2004._617-1_
2004-01-01
Abstract:There is a problem of vibration in a diagnosis system of helical evaporator tubes installed in a nuclear power station. Numerical simulations are implemented on the assumption that the vibration is caused by the Coulomb's friction. An analytical model is derived as a large scale nonlinear vibration system and a lot of computational cost would be required to carry out the simulations. The Transfer Influence Coefficient Method, which has high accuracy and efficiency in numerical computations, is applied and efficiently implements the simulations. The vibrations are qualitatively reproduced by the simulations. It enables us to make a pre-evaluation of several means to suppress the vibration and the most effective devise is expected through the simulation.
What problem does this paper attempt to address?