Ultra-long-period fiber grating cascaded to a knob-taper for simultaneous measurement of strain and temperature

Chengguo Tong,Xudong Chen,Yu Zhou,Jiang He,Wenlei Yang,Tao Geng,Weimin Sun,Libo Yuan
DOI: https://doi.org/10.1007/s10043-018-0419-2
IF: 1.2
2018-03-03
Optical Review
Abstract:This study presents a simple Mach–Zehnder interferometer (MZI) to obtain the bimodal characteristics that realize simultaneous measurement of strain and temperature through cascading an ultra-long-period fiber grating and a knob-shaped taper. We obtain the multi-dip feature from the MZI, and the Dips 2 and 5 are selected from 11 interference dips. Experimental results indicated that the wavelength sensitivities of Dips 2 and 5 are − 0.54 nm mε−1 and 0.058 nm °C−1, and − 0.53 nm mε−1 and 0.055 nm °C−1 to strain and temperature, respectively. The depth sensitivities are − 3.3 dB mε− 1, − 0.015 dB °C−1 and −5.8 dB mε−1, and 0.06 dB °C−1 for Dips 2 and 5, respectively. It is concluded that the proposed structure is suitable for simultaneous strain and temperature measurements.
optics
What problem does this paper attempt to address?