Gd-EOB-DTPA-enhanced T1 relaxometry for assessment of liver function determined by real-time 13C-methacetin breath test

Michael Haimerl,Irene Fuhrmann,Stefanie Poelsterl,Claudia Fellner,Marcel D. Nickel,Kilian Weigand,Marc H. Dahlke,Niklas Verloh,Christian Stroszczynski,Philipp Wiggermann
DOI: https://doi.org/10.1007/s00330-018-5337-y
IF: 7.034
2018-03-12
European Radiology
Abstract:ObjectivesTo determine whether liver function as determined by intravenous administration of 13C-methacetin and continuous real-time breath analysis can be estimated quantitatively from gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) relaxometry.MethodsSixty-six patients underwent a 13C-methacetin breath test (13C-MBT) for evaluation of liver function and Gd-EOB-DTPA-enhanced T1-relaxometry at 3 T. A transverse 3D VIBE sequence with an inline T1 calculation based on variable flip angles was acquired prior to (T1 pre) and 20 min post-Gd-EOB-DTPA (T1 post) administration. The reduction rate of T1 relaxation time (rrT1) and T1 relaxation velocity index (∆R1) between pre- and post-contrast images was evaluated. 13C-MBT values were correlated with T1post, ∆R1 and rrT1, providing an MRI-based estimated 13C-MBT value. The interobserver reliability was assessed by determining the intraclass correlation coefficient (ICC).ResultsStratified by three different categories of 13C-MBT readouts, there was a constant increase of T1 post with increasing progression of diminished liver function (p ≤ 0.030) and a constant significant decrease of ∆R1 (p ≤ 0.025) and rrT1 (p < 0.018) with progression of liver damage as assessed by 13C-methacetin breath analysis. ICC for all T1 relaxation values and indices was excellent (> 0.88). A simple regression model showed a log-linear correlation of 13C-MBT values with T1post (r = 0.57; p < 0.001), ∆R1 (r = 0.59; p < 0.001) and rrT1 (r = 0.70; p < 0.001).ConclusionLiver function as determined using real-time 13C-methacetin breath analysis can be estimated quantitatively from Gd-EOB-DTPA-enhanced MR relaxometry.Key Points• Gd-EOB-DTPA-enhanced T1 relaxometry quantifies liver function• Gd-EOB-DTPA-enhanced MR relaxometry may provide parameters for assessing liver function before surgery• Gd-EOB-DTPA-enhanced MR relaxometry may be useful for monitoring liver disease progression• Gd-EOB-DTPA-enhanced MR relaxometry has the potential to become a novel liver function index
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?