Experimental Characterization and Modeling of Thermal Contact Resistance of Electric Machine Stator-to-Cooling Jacket Interface Under Interference Fit Loading

J. Emily Cousineau,Kevin Bennion,Victor Chieduko,Rajiv Lall,Alan Gilbert
DOI: https://doi.org/10.1115/1.4039459
2018-05-08
Journal of Thermal Science and Engineering Applications
Abstract:Cooling of electric machines is a key to increasing power density and improving reliability. This paper focuses on the design of a machine using a cooling jacket wrapped around the stator. The thermal contact resistance (TCR) between the electric machine stator and cooling jacket is a significant factor in overall performance and is not well characterized. This interface is typically an interference fit subject to compressive pressure exceeding 5 MPa. An experimental investigation of this interface was carried out using a thermal transmittance setup using pressures between 5 and 10 MPa. The results were compared to currently available models for contact resistance, and one model was adapted for prediction of TCR in future motor designs.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?