Comparison of diffusion-weighted MRI and anti-Stokes Raman scattering (CARS) measurements of the inter-compartmental exchange-time of water in expression-controlled aquaporin-4 cells

Takayuki Obata,Jeff Kershaw,Yasuhiko Tachibana,Takayuki Miyauchi,Yoichiro Abe,Sayaka Shibata,Hiroshi Kawaguchi,Yoko Ikoma,Hiroyuki Takuwa,Ichio Aoki,Masato Yasui
DOI: https://doi.org/10.1038/s41598-018-36264-9
IF: 4.6
2018-12-01
Scientific Reports
Abstract:We performed multi-b and multi-diffusion-time diffusion-weighted magnetic resonance imaging on aquaporin-4-expressing (AQ) and -non-expressing (noAQ) cells, and demonstrated a clear difference between the signals from the two cell types. The data were interpreted using a two-compartment (intra and extracellular spaces) model including inter-compartmental exchange. It was also assumed that restricted diffusion of water molecules inside the cells leads to the intracellular diffusion coefficient being inversely proportional to the diffusion-time. Estimates of the water-exchange-times obtained with this model are compared to those measured using an independent optical imaging technique (coherent anti-Stokes Raman scattering imaging, CARS). For both techniques it was found that the exchange-time estimated for the noAQ cells was significantly longer than that for the AQ cells.
multidisciplinary sciences
What problem does this paper attempt to address?