Stress states caused in chamber of reinforced concrete grain silo by non-centric emptying on large eccentricities

Jolanta Anna Prusiel,Krzysztof Gierej
DOI: https://doi.org/10.2478/sgem-2018-0043
2018-12-01
Studia Geotechnica et Mechanica
Abstract:Abstract The article presents the analysis of complex stress states in the concrete structure of grain silos, caused by non-centric emptying. The authors present a combination of loads from the pressure of bulk solid on the silo chamber according to Eurocode 1, Part 4 [11], which should be taken into account when emptying on large eccentricities in action assessment class 3 (AAC3) silos. For the example of a cylindrical wheat silo with a height of 25 m and a diameter of 10 m, the researchers carried out an analysis regarding the impact of the size of the eccentric discharge outlet on the distributions of forces and bending moments in a reinforced concrete wall.
What problem does this paper attempt to address?