Selective occlusion of splenic artery aneurysms with the coil packing technique: the impact of packing density on aneurysm reperfusion correlated between contrast-enhanced MR angiography and digital subtraction angiography

Mikołaj Wojtaszek,Krzysztof Lamparski,Emilia Wnuk,Tomasz Ostrowski,Rafał Maciąg,Thomas Rix,Edyta Maj,Krzysztof Milczarek,Krzysztof Korzeniowski,Olgierd Rowiński
DOI: https://doi.org/10.1007/s11547-019-00993-2
2019-02-02
La radiologia medica
Abstract:<h3 class="a-plus-plus">Abstract</h3> <span class="a-plus-plus abstract-section id-a-sec1"> <h3 class="a-plus-plus">Purpose</h3> <p class="a-plus-plus">The aim was to evaluate the relationship between coil packing densities after splenic artery aneurysm (SAA) treatment using detachable microcoils and rates of SAA reperfusion and to suggest a post-treatment surveillance protocol using contrast-enhanced MRA.</p> </span> <span class="a-plus-plus abstract-section id-a-sec2"> <h3 class="a-plus-plus">Materials and methods</h3> <p class="a-plus-plus">Evaluated were 16 patients (4 men; mean age 46.7), who underwent true SAA embolization using detachable microcoils (Concerto, Medtronic). SAAs were treated by selective coil packing (CP) or stent-assisted coil exclusion (SAC). Contrast-enhanced magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) were performed at 3 months post-procedure and correlated.</p> </span> <span class="a-plus-plus abstract-section id-a-sec3"> <h3 class="a-plus-plus">Results</h3> <p class="a-plus-plus">Primary CP was used in 13 patients, while SAC was used in three patients. On follow-up, complete aneurysm occlusion was seen in seven patients (43.8%). Sac reperfusion occurred in nine patients (56.2%) and was demonstrated in all CE-MRA and six DSA studies. Mean aneurysm packing density was 20.10 ± 8.05% for the CP group and 32.90 ± 11.95% for the SAC group (<em class="a-plus-plus">p</em> = 0.038). There was a significant difference in the incidence of aneurysm sac reperfusion on CE-MRA study between CP and SAC (9 vs. 0). No sac reperfusion was seen in aneurysms with packing densities ≥ 29%, irrespective of either embolization method.</p> </span> <span class="a-plus-plus abstract-section id-a-sec4"> <h3 class="a-plus-plus">Conclusion</h3> <p class="a-plus-plus">Favorable midterm results for coil packing of SAAs seem to depend on the coil packing density with a coil volume approximately a quarter of the aneurysm volume being most effective. Follow-up should involve the use of CE-MRA as this modality has been shown to be superior over DSA in detecting aneurysm reperfusion and coil compaction.</p> </span> <span class="a-plus-plus abstract-section id-a-sec5"> <h3 class="a-plus-plus">Level of evidence</h3> <p class="a-plus-plus">Level IV, therapeutic study.</p> </span>
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?