Guideline of inductively coupled plasma mass spectrometry “ICP–MS”: fundamentals, practices, determination of the limits, quality control, and method validation parameters

Mostafa F. Al-Hakkani
DOI: https://doi.org/10.1007/s42452-019-0825-5
2019-06-26
SN Applied Sciences
Abstract:The objective of this work is, the introduction of a quick guideline for the ICP–MS users to have a look on the theory, composition, some of the quality control and quality assurance definitions and demands, reagents preparation, detection limits calculation, method validation parameters of ICP–MS method of analysis.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to provide a quick guide for ICP - MS (Inductively Coupled Plasma - Mass Spectrometry) users, covering theoretical basis, components, definitions and requirements of quality control and assurance, reagent preparation, detection limit calculation, and method validation parameters, etc. Specifically, it aims to help users: 1. **Understand the basic principles of ICP - MS**: including its composition structure, working process and its application in elemental analysis. 2. **Master the requirements of quality control and quality assurance**: to ensure the accuracy and reliability of experimental results. 3. **Learn how to prepare reagents**: to ensure the accuracy in the sample processing and analysis process. 4. **Understand and calculate the detection limit**: to determine the lowest concentration that the instrument can reliably detect. 5. **Be familiar with method validation parameters**: to ensure the effectiveness and applicability of the methods used. Through these contents, the paper hopes that ICP - MS users can better understand and use this technology, thereby improving experimental efficiency and data quality. ### Key Point Summary - **Theoretical Basis**: introduce the working principle of ICP - MS and its importance in trace element analysis. - **Quality Control and Assurance**: definitions and requirements to ensure the accuracy and consistency of experimental results. - **Reagent Preparation**: detailedly explain the preparation methods of reagents such as water, acid, and gas. - **Detection Limit Calculation**: introduce several commonly - used detection limit calculation methods, such as IDL (Instrument Detection Limit), LOD (Limit of Detection), MDL (Method Detection Limit), etc. - **Method Validation Parameters**: ensure the effectiveness and reliability of the analysis method. Through these contents, the paper provides comprehensive guidance for ICP - MS users, helping them better apply this technology in practical operations.