Towards Enhancing the Effectiveness of Classroom Designs for Natural Ventilation Comfort in Yola, Nigeria

Ikechukwu Ogwu,Zhi Lin Long,Olusegun Moses Idowu,Moses Okonkwo,Ogwu Ikechukwu,Long Zhi Lin,Idowu Olusegun Moses,Okonkwo Moses
DOI: https://doi.org/10.4236/ojee.2019.83008
2019-01-01
Open Journal of Energy Efficiency
Abstract:Given the perennial incidence of thermal discomfort, health issues, as well as energy costs associated with naturally ventilated classrooms in Yola, the study aimed at enhancing the effectiveness of classroom designs for natural ventilation comfort by examining the effects of six architectural design variables—size and position of openings, form of buildings, orientation of buildings, site planning, topography, and physical features, on the ventilation coefficients of 61 classrooms selected from nine stratified clusters in Yola, Adamawa State, Nigeria. Data were analyzed using percentages, ratios, means as well as standard deviation, and then sorted in groups using tables. The study revealed that the form and orientation of the classroom-buildings, as well as topography, site planning and other physical features, have no significant effect on ventilation coefficient. In addition, a new mean ventilation coefficient was obtained in ten classrooms against an earlier claim that ventilation coefficient cannot exceed a fixed average regardless of the ratio of wall opening to floor area.
What problem does this paper attempt to address?