Measuring AC/DC hybrid electric field using an integrated optical electric field sensor

Hai Wang,Rong Zeng,Chijie Zhuang,Gang Lyu,Junjie Yu,Ben Niu,Chanxiao Li
DOI: https://doi.org/10.1016/j.epsr.2019.106087
IF: 3.818
2020-02-01
Electric Power Systems Research
Abstract:Measuring the AC and DC hybrid electric field is significant for the electromagnetic environment evaluation and for the design of AC/DC hybrid transmission lines. In this paper, a measuring method for both DC and AC electric field measurement by the integrated optical electric field sensor was proposed. The DC electric field can be measured by rotating the sensor by a servomotor which modulates the DC signals into AC signals. A measuring system was implemented and calibrated. A field measurement under an AC/DC hybrid transmission line in Jeju Island, Korea was carried out, and the measured data of the electric field under different DC operating modes were obtained. The results obtained by the proposed method were in reasonably good agreement with a commercial AC probe and the computed DC electric field.
engineering, electrical & electronic
What problem does this paper attempt to address?