Conductometric sensor for viable Escherichia coli and Staphylococcus aureus based on magnetic analyte separation via aptamer

Xuzhi Zhang,Xiaochun Wang,Qianqian Yang,Xiaoyu Jiang,Yang Li,Jun Zhao,Keming Qu
DOI: https://doi.org/10.1007/s00604-019-3880-0
IF: 5.7
2019-12-12
Microchimica Acta
Abstract:A method is described to determine viable populations of <em class="EmphasisTypeItalic">Escherichia coli</em> (<em class="EmphasisTypeItalic">E. coli</em>) and <em class="EmphasisTypeItalic">Staphylococcus aureus</em> (<em class="EmphasisTypeItalic">S. aureus</em>). The method employs aptamer-magnetic separation combined with resistivity based detection. The bacteria were separated by means of aptamer-functionalized magnetic beads. They were then quantified by measuring their growth kinetics through time-dependent conductivity changes of culture media. The time-course of growth was logged by real-time and contactless measurements that yielded starting concentrations from the duration of lag intervals prior to the log phase of growth. In pure water samples, the linear ranges for measuring <em class="EmphasisTypeItalic">E. coli</em> and <em class="EmphasisTypeItalic">S. aureus</em> cells are 2.5 × 10<sup>3</sup>–2.5 × 10<sup>8</sup> CFU·mL<sup>−1</sup> and 4.1 × 10<sup>3</sup>–4.1 × 10<sup>8</sup> CFU·mL<sup>−1</sup>, respectively. In spiked tap water samples, the lower limits of detection are 2.3 × 10<sup>4</sup> CFU·mL<sup>−1</sup> and 4.0 × 10<sup>3</sup> CFU·mL<sup>−1</sup> for <em class="EmphasisTypeItalic">E. coli</em> and <em class="EmphasisTypeItalic">S. aureus</em>, with recoveries of 87.0–108.7% and 92.5–105.0%, respectively. The relative standard deviation of these measurements (10.0%) is below that of plate counting method (13.9%). The presence of micro/nanoparticles such as magnetic beads or selenium nanoparticles in the culture media does not interfere, unlike in case of automatted optical density monitoring. The <em class="EmphasisTypeItalic">E. coli</em> and <em class="EmphasisTypeItalic">S. aureus</em> cells captured on the aptamer-functionalized magnetic beads can be directly tested for their susceptibility to antibiotics. The process of magnetic separation and determination of load burden requires neither bulky, sophisticated equipment nor expensive reagents.Aptamer-functionalized magnetic beads are used to selectively capture and separate <em class="EmphasisTypeItalic">E. coli</em> and <em class="EmphasisTypeItalic">S. aureus</em> cells in aqueous samples. They are directly transferred to a multichannel conductometric sensor for the quantification of viable bacteria via automated monitoring of their growth kinetics.
chemistry, analytical
What problem does this paper attempt to address?