Modelling the performance of a new cooling unit for refrigerated transport using carbon dioxide as the refrigerant

Paolo Artuso,Sergio Marinetti,Silvia Minetto,Davide Del Col,Antonio Rossetti
DOI: https://doi.org/10.1016/j.ijrefrig.2020.02.032
IF: 4.14
2020-07-01
International Journal of Refrigeration
Abstract:This paper provides a theoretical assessment of the thermal performance of a new CO2 vapor-compression system for refrigerated transport applications. Three different configurations are investigated: the standard back-pressure with low pressure receiver lay-out and two arrangements integrating a two-phase ejector. In particular, the use of an auxiliary evaporator in the outlet line of the ejector is considered, to extend the ejector operating range. A numerical model of the system is developed and its theoretical performance is discussed for different values of internal space temperature and external ambient temperature. Simulations' results show that the ejector cycle configuration is convenient when the system is operating in a hot climate with a maximum COP increase (compared to the traditional configuration) equal to 15.9%, at 42°C ambient temperature and -5°C internal space temperature. The use of an auxiliary evaporator can extend the operating range of the ejector to lower values of ambient temperature, with a maximum COP improvement (over the traditional configuration) equal to 14.1% at 25°C ambient temperature and 5°C internal cargo space.
engineering, mechanical,thermodynamics