Effect of installation height of indoor unit on field heating performance of room air conditioner

Zixu Yang,Hansong Xiao,Changqi Ji,Baolong Wang,Wenxing Shi
DOI: https://doi.org/10.1016/j.jobe.2020.101527
IF: 7.144
2020-11-01
Journal of Building Engineering
Abstract:The room air conditioner (RAC) is considered the most suitable space heating method for residential buildings without domestic heating in the mild climate zone. The heating performance of RACs has been well researched in laboratories. However, the field performance of RACs is far from the laboratory experimental results owing to their installation and maintenance procedures. This study investigates the impact of the indoor unit installation height of RACs on their field performance during heating. By adjusting the height of the indoor unit, the energy performance and thermal sensation indexes are verified. An experiment is carried out to test the thermal comfort and energy performance simultaneously, which comparatively reflects the difference between different installation heights. The indoor air temperature and related parameters, predicted mean vote, vertical temperature difference, floor temperature, draft, and asymmetric thermal radiation are used to evaluate the indoor comfort. The heat capacity and coefficient of performance are used to assess the energy performance. Experimental results show that the installation height of the indoor unit affects the energy performance significantly. Generally, the heat capacity and coefficient of performance for lower installation heights are higher than those for higher installation heights. Furthermore, lower the installation position, the easier it is to create a comfortable indoor environment.
construction & building technology,engineering, civil
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the influence of the installation height of indoor air - conditioners on the actual heating performance. Specifically, the research aims to explore the changes in the energy performance and thermal comfort of indoor air - conditioning units in the heating mode at different installation heights. By adjusting the installation height of the indoor unit, the changes in energy performance and thermal sensation indicators were experimentally verified, in order to find the optimal installation height, thereby ensuring the thermal comfort of indoor occupants while improving energy efficiency. ### Background and Problem of the Paper With the rapid increase in the energy consumption of residential buildings, energy supply and environmental changes have become problems that urgently need to be solved in recent years. According to statistics, there are currently more than 1.93 billion room air conditioners (RACs) in use globally, resulting in a significant increase in residential electricity consumption. Compared with other heating devices such as gas boilers and electric heaters, RACs are more energy - efficient because they absorb additional heat from the outside air, so they are widely used as residential heating devices in areas without central heating systems. However, due to differences in installation and maintenance procedures, the actual performance of RACs is often far lower than the laboratory test results. Especially during the heating period, since the supply air temperature of the indoor unit is much higher than the indoor temperature, hot air rises due to buoyancy, resulting in a significant temperature gradient in the vertical direction, making occupants feel uncomfortable and affecting the thermodynamic performance of RACs. ### Research Objectives This research analyzed the energy performance and thermal comfort of indoor RAC units at different installation heights through experimental methods. The specific objectives of the research include: 1. **Energy Performance**: Evaluate the influence of different installation heights on the heating capacity and coefficient of performance (COP) of RACs. 2. **Thermal Comfort**: Evaluate the thermal comfort at different installation heights by measuring indicators such as indoor air temperature, predicted mean vote (PMV), predicted percentage of dissatisfied (PPD), vertical temperature difference, floor temperature, air flow, and asymmetric thermal radiation. ### Experimental Methods The experiment was carried out in a laboratory simulating a real - life residential environment. The laboratory was divided into two chambers, indoor and outdoor, simulating the actual residential room and the external environment respectively. A 1.5 - horsepower RAC was used as the test object in the experiment. By adjusting the installation height of the indoor unit (2.2 meters and 1.0 meter respectively), various performance indicators were recorded and analyzed. ### Main Conclusions The experimental results show that the installation height of the indoor unit has a significant impact on the energy performance and thermal comfort of RACs. The specific conclusions are as follows: - **Energy Performance**: The heating capacity and COP at the lower installation height (1.0 meter) are higher than those at the higher installation height (2.2 meters). The experimental data shows that the total heating capacity at the lower installation height is increased by 5.1%, and the COP is also slightly increased. - **Thermal Comfort**: The lower installation height is more likely to create a comfortable indoor environment. The temperature distribution is more uniform, the vertical temperature difference is smaller, and the floor temperature is higher, which helps to improve the comfort of the feet. ### Formula Summary - **Heating Capacity Calculation Formula**: \[ Q_{\text{heating}}=(h_2 - h_1)\times\dot{m}+(h_4 - h_3)\times\dot{m}-P_{\text{loss}} \] where \(h_2\) and \(h_1\) are the enthalpy values at the compressor outlet and inlet respectively, \(h_4\) and \(h_3\) are the enthalpy values at the condenser inlet and outlet respectively, \(\dot{m}\) is the mass flow rate of the refrigerant, and \(P_{\text{loss}}\) is the heat loss of the compressor. - **Coefficient of Performance (COP) Calculation Formula**: \[ \text{COP}=\frac{Q_{\text{heating}}}{P_{\text{com}}} \] where \(P_{\text{com}}\) is the input power of the compressor. - **Energy Utilization Coefficient (EUC) Calculation Formula**: \[ \text{EUC}=\frac{t_{\text{uz}}-t_{\text{s}}}{t_{\text{oz}}-t_{\text{s}}} \] where \(t_{\text{uz}}\) is the average temperature in the unoccupied area.