Rapid Detection to Differentiate Hypervirulent Klebsiella pneumoniae (hvKp) From Classical K. pneumoniae by Identifying peg-344 With Loop-Mediated Isothermal Amplication (LAMP)

Wenjian Liao,Dan Long,Qisen Huang,Dandan Wei,Xiaobing Liu,Lagen Wan,Yuling Feng,Wei Zhang,Yang Liu
DOI: https://doi.org/10.3389/fmicb.2020.01189
IF: 5.2
2020-06-04
Frontiers in Microbiology
Abstract:<span><b>Objectives:</b> To establish a rapid molecular diagnostics of hvKp using the <i>peg-344</i> loop-mediated isothermal amplification technique (LAMP).<b>Methods:</b> In all, 28 <i>K. pneumoniae</i> strains isolated from the blood of patients were used for the <i>peg-344</i> LAMP. <i>K. pneumoniae</i> NTUH-K2044 and <i>K. pneumoniae</i> ATCC700603 were used as positive control and negative control, respectively. For comparison, all the results were detected in a polymerase chain reaction (PCR), which was considered the gold standard for the detection of the gene. Mouse lethality assay, and Serum killing assay were also used to determine the virulence phenotype of <i>K. pneumoniae</i>.<b>Results:</b> We determined the specificity and sensitivity of the primers for <i>peg-344</i> detection in the LAMP reactions. This LAMP assay was able to specifically differentiate hvKp from classical <i>K. pneumoniae</i> (cKp) at 65°C, which was 100-fold more sensitive than a PCR assay for <i>peg-344</i> detection. The virulence phenotype of <i>K. pneumoniae</i> detected by LAMP was as precise as by Mouse lethality assay and Serum killing assay.<b>Conclusion:</b> The LAMP assay is easy to perform and rapid. Therefore, it can be routinely applied to differentiate hvKp from cKp in the clinical laboratory.</span>
microbiology
What problem does this paper attempt to address?