Evaluation of diagnostic accuracy of the wabG gene based Klebsiella pneumoniae detection by loop-mediated isothermal reaction in neonatal blood sample

Shukla Banerjee,Mithun H K,K Sudhakara Prasad,Rajesh P Shastry
DOI: https://doi.org/10.1016/j.diagmicrobio.2024.116552
Abstract:Neonatal sepsis is a significant problem in developing nations, but current gold-standard diagnostic methods, such as blood culture, is slow and time-consuming. Here, we describe the development of a colorimetric loop-mediated isothermal amplification (LAMP) assay that targets the wabG gene in the lipopolysaccharide region of K. pneumoniae, offering a limit of detection (LOD) of 40 CFU/ml with specificity for K. pneumoniae compared to other non-Klebsiella strains. The sensitivity and specificity of the LAMP assay were found to be 90 % and 100 %, respectively, with a positive predictive value of 100 % and a negative predictive value of 96.47 %. The LAMP assay demonstrated a significantly shorter turnaround time of 1 h. The LAMP assay was found to be simpler, quicker, and more sensitive than traditional detection techniques such as PCR and blood culture.
What problem does this paper attempt to address?