Influence of electrolyte concentration on static and dynamic Lead-Acid battery

M Ghufron,Istiroyah,C A Perwita,Masruroh,N Khairati,F R Ramadhan,Y E Setiawan,K B Pranata
DOI: https://doi.org/10.1088/1742-6596/1595/1/012012
2020-07-01
Journal of Physics: Conference Series
Abstract:Abstract Electrolyte concentration is one of the important parameters on Lead-Acid Battery (LAB) outcome. Lead-acid battery has been made with static and dynamic electrolyte treatment where 4 variations of electrolyte concentration (20%, 30%, 40% and 50%) and 1A current applied in the system during charging-discharging test to analyze the relationship of the electrolyte concentration to the battery characteristic and compare static and dynamic lead-acid battery performance. The experiment result that for dynamic lead acid battery, the capacity increases along with the higher concentration from 20% to 40% but decrease at 50% compare to 40% for 3 first cycle charge-discharge test when the static lead-acid battery unwork at concentration 20% and show the increases capacity along with increases concentration. In capacity and efficiency point of view, dynamic lead-acid show better performance compare to static lead-acid battery.
What problem does this paper attempt to address?