Thermal effect and optimal design of cooling pipes on mass concrete with constant quantity of water flow

Yongxing Hong,Ji Lin,Kambiz Vafai
DOI: https://doi.org/10.1080/10407782.2020.1805222
2020-08-21
Abstract:To study the heat transfer of pipe cooling process in concrete, an effective model combined with a radial basis function collocation method (RBFCM) is proposed. In this model, a replicable fictitious structure is imported that allows a set of fixed points to supersede the complicated adaptive remeshing or redistributing points, which significantly saves a lot of time and effort in the pre-processing of the numerical algorithm. Moreover, a relation between the mean temperature of water flow and the heat flux is derived from a heat balance equation. The validity of the proposed model is demonstrated in simulation of a typical three-dimensional problem. Numerical solutions are compared with those obtained by the finite element method and some experimental data. To find the optimum design, 32 cases involving 1 to 7 pipes under certain constraints are considered as follows: the quantity of water flow remains unchanged, the volume occupied by pipes keeps the same, and the same initial temperature of water is used for cooling. Since number, size, and positions of pipes are always changing during the design process, the ability of this approach is further illuminated. Finally, the effect of water flow with several conversing frequencies is investigated. As expected, the maximum temperature difference in concrete can be further controlled by enlarging conversing frequency. Numerical results reveal that the optimal design of pipe cooling system can not only minimize temperature, but also control temperature difference of the concrete structure. The process of design is useful for guidance of engineering practice to improve the structural safety and the economy of the whole building process.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the thermal effect and optimal design of cooling water pipes in mass concrete. Specifically, the research aims to: 1. **Study the influence of cooling water pipes on the internal temperature field of concrete**: By introducing an effective model combined with the Radial Basis Function Collocation Method (RBFCM), the heat transfer process of cooling water pipes in concrete is simulated. This model allows a set of fixed points to replace complex adaptive re - meshing or redistributed points, thus greatly saving the time and effort of numerical algorithm pre - processing. 2. **Derive the relationship between the average temperature of water flow and heat flux**: Starting from the heat balance equation, establish the mathematical relationship between the two to ensure the accuracy and reliability of the model. 3. **Optimize the design of cooling water pipes**: Under certain constraints (such as keeping the water flow constant, the same volume occupied by the pipes, and the same initial cooling water temperature), consider the influence of different numbers, sizes, and positions of cooling water pipes on the concrete temperature field to find the optimal design scheme. Research shows that increasing the heat exchange frequency can further control the maximum temperature difference in concrete. 4. **Improve the structural safety and economy in engineering practice**: By optimizing the design of the cooling water pipe system, not only can the maximum temperature of concrete be reduced, but also the temperature difference within the concrete structure can be effectively controlled, providing guidance for actual projects and improving the safety and economy of the entire construction process. ### Mathematical Model To achieve the above - mentioned goals, the paper has established the following mathematical models: #### Governing Equations and Boundary Conditions In concrete, the governing equation is: \[ \rho_c C_c \frac{\partial T(x,y,z,t)}{\partial t}=K_c \nabla^2 T(x,y,z,t)+\rho_c C_c \frac{\partial h(t)}{\partial t} \] where: - \(T\) represents temperature. - \(\rho_c\) and \(C_c\) represent the density and specific heat capacity of concrete respectively. - \(K_c\) represents the thermal conductivity of concrete. - \(h(t)\) represents the adiabatic temperature rise, which can be obtained through experiments. The third - type boundary condition is used to describe the heat exchange between the concrete surface and the environment: \[ K_c \frac{\partial T(x,y,z)}{\partial n}=b_e (T_e - T(x,y,z)) \] where: - \(n\) is the normal vector. - \(T_e\) is the environmental temperature. - \(b_e\) is the convective heat transfer coefficient between the concrete and the contact environment. #### Temperature Change of Water Flow along the Pipeline Assume that the water flow is laminar, and apply Newton's law of cooling to simulate the heat transfer from concrete to the cooling system: \[ dQ = 2\pi R_{out} Q_c dl dt \] where: - \(R_{out}\) and \(R_{in}\) are the outer and inner radii of the pipeline respectively. - \(Q_c\) is the heat flux transferred from concrete to the cooling system. According to the heat balance equation: \[ dQ = dQ_w + dQ_s \] where: - \(dQ_w\) is the energy change of water. - \(dQ_s\) is the energy retained in the steel pipe. Finally, the expression of water flow temperature \(T_{wn}\) is obtained: \[ T_{wn}=T_{w0}+\frac{n c}{c - T_{1 \rightarrow n}^w}\left(1 - n v \max(T_c)\right) \] where: \[ c=\frac{2 R_{out} b_w \Delta t}{R_{in}^2 q_w C_w}, \quad v=\frac{R_{out}^2 - R_{in}^2}{q_c C_c \Delta t} \] Through these models and equations, researchers can effectively simulate and optimize the cooling water pipe system, thereby improving the safety and economy of mass concrete structures.